Fire Alarm System
Honeywell fire alarm systems have always been a leader in the fire safety industry, from the research and development of new products, to create more efficient production processes, constantly setting higher industry standards through the strength of partners cooperation to provide high-level fire alarm systems in many countries around the world. Honeywell always committed to provide customers with high standard of product and effective support.
STAR PRODUCTS OF FIRE ALARM SYSTEM
NX30 Intelligent Addressable Fire Alarm Panel
The NX30 is an UL approved intelligent Fire Alarm Control Panel designed for medium to large-scale facilities. 1 to 14 SLC. Connect up to 99 detectors and 99 modules per loop or 1386 detectors and 1386 modules per FACP in Clip protocol. Standard network for up to 64 nodes (NX30, N-NCS Workstation). Large colorful 7” graphic TFT LCD. Colorful backlit status indicator LEDs on the top of the display panel to indicate the panel status. Quick menu design to shorten operation. Modular design with aluminum housing of CPU, loop card and Network card to protect PCBA effectively. Plug and Play for cable and clip-on for the loop card and CPU card for easy installation. Optimized the operation time by simplifying the inquiry step to 2 steps in 2 seconds. Redesigned the buttons to prolong the lifecycle. Only 50mm thick Remote Annunciator with touch pad for both surface and flush mount. Based on CAN bus, it can connect up to maximum 64 Remote Annunciator, with longest communication distance between 2 annunciators cover 1km, total transmission length is 64km. Simplified manual with key message such as wiring manual on the back of the cabinet door. Modbus interface to 3rd party system.
Applications: high end residential buildings, hotels, commercial buildings.
Available regions: ASEAN
New 951G Series Intelligent Detector and 9G Series modules
New 951G Series intelligent detector and modules with UL and FM approval can be connected to NX30 panel in CLIP protocol. Smoke detector is designed to meet UL 268 7th Edition. Dual-Angle™ optical detection technology can sense a wider range of combustion sources and their smoke, with high resistance to false alarms from cooking smoke and vapor. Both smoke detector and Fix/ROR Heat detector are sleek, low-profile, stylish design, support electronic addressing, integral communications and built-in device-type identification, built-in functional test switch activated by external magnet. Support Flashscan and CLIP protocol along with different modules and panel. When using N951G with 9G modules on NX30, it supports 99 detectors and 99 modules in CLIP protocol but when N951G and 851 Series modules or Wenlock modules connect to NFS2-3030, it supports 159 detectors and 159 modules in Flashscan protocol. Remote test feature is available from panel. Walk test with address display available in FlashScan system only. 9G Series modules have control module, control/monitor module, zone monitor module, Monitor module, Isolator module, and Manual Call Point. They all support electronic addressing. All these are UL approved, and all are FM approved also except Manual Call Point.
Applications: places with larger people flow, valuable property or particularly important operational continuity, such as airports, subways, data centers, and high-tech factories. It also suitable for indoor spaces with higher requirements for the aesthetics of internal devices, such as hotels and apartments.
Available regions: coming soon
N6000 Intelligent Addressable Fire Alarm System
N6000 is an intelligent Fire Alarm Control Panel designed for medium size facilities. With 2 to 16 SLCs, total capacity of 1,584 or 3,168 addressable devices per FACP. 1060 character LCD presents vital information such as fire situation, fire progression and evacuation details. A host of other options, such as firefighters’ telephone, LED or LCD annunciators, integral printer are available. CCC approved.
Applications: residential buildings, office complexes, schools, college campuses and any other utilities to provide open area protection.
Available regions: ASEAN
751 Series Devices
Compatible with N6000 Fire Alarm Control Panel in CLIP protocol. Photoelectric Smoke Detector use red and blue dual light source LED detection technology, enhanced false alarm immunity. Smoke detector may also available with a built-in sounder and remote LED output. Heat detector is available with Fix or Fix/ROR. Available with Control Module, Relay/Monitor Module, Isolator module, Monitor Module, Interface Monitor Module, MCP and Horn Strobe. Software addressing. CCC approved.
Applications: residential buildings, office complexes, schools, college campuses and any other utilities to provide open area protection。
Available regions: ASEAN
Alarm Bells
System Sensor SSM/SSV Series and SSL24-6 Alarm Bells are low current, high decibel notification appliances. The Alarm Bells provide loud resonant tones. The SSM series (SSL24-6) operates on 12/24VDC (24VDC) and are motor driven, while the SSV series operates on 120VAC utilizing a vibrating mechanism. The alarm bell is polarized for use with supervision circuitry and have under dome strikers and operating mechanisms.
Applications: fire and burglary system and other signaling applications
Available regions: ASEAN, Australia & New Zealand, India, META, North America
WFD Waterflow Detector
System Sensor WFD Series is compatible with schedule 10 through 40 steel pipe, sizes 2” through 8”, and can be mounted in a vertical or horizontal position. NEMA 4 rated. WFDT Vane-type waterflow detector fits any tee that has a 1” branch. UL and FM approval.
Applications: commercial building, hotels, metro, hospitals, applications with fire fighting pipes.
Available regions: ASEAN, Australia & New Zealand, India, META
5600 Series Mechanical Heat Detector
5600 Series mechanical heat detectors offer a low-cost means for property protection against fire, and for non-life-safety installations where smoke detectors are inappropriate. A full-line of configurations to accommodate a broad range of applications. Consists of both single and dual circuit heat detectors featuring fixed temperature thermal sensor or combination fixed temperature/ROR, with temperature ratings 135oF (57oC) or 194oF (90oC). The ROR element of the fixed /ROR models is restorable to accommodate field-testing. UL and FM approved.
Applications: garage and warehouse.
Available regions: ASEAN, India, North America